← All results

01 / 06 · NEXT-DOSE PREDICTION

Predicting the next dose in a new cell type

In U2OS cells, Celmio Harley explained twice as much of the difference between compounds as the starting estimate (R² 0.21 → 0.42).

See the data
2×

the difference between compounds explained, compared with the starting estimate

THE QUESTION

Can a low-dose measurement predict the response at the next dose?

Raising the dose changes how cells look and behave. The question here: in a new cell type where only the lower dose has been measured, can data you already have predict that change?

How we tested it

In U2OS cells, the next-dose responses of 292 compounds were kept aside. Celmio Harley predicted them from a starting estimate, the experiments in memory and the same compound in a reference cell line. The predictions were then scored against the real measurements.

RESULTS

0.21 → 0.42

R² between compounds: starting estimate → Celmio Harley

292 U2OS compounds; Figure 1d.

43.0%

lower error than simply predicting the average response

U2OS, full reference set; Table 2.

5.5%

lower error than a linear model given the same data

U2OS; Table 2.

Figure 1d; Supplementary Table 22

How much of the difference between compounds is explained

Download CSV
Between-compound R²
Starting estimate
0.210
Celmio Harley
0.419
Repeat measurement
0.891
00.501

U2OS · 292 compounds · 1,168 conditions. R² between compounds, averaged over 12 test groups; thin lines show 95% intervals.

Figure 1b,c; archived pemetrexed example

One prediction, feature by feature

Download full CSV
Slide to read each feature
PredictionMeasurement

Pemetrexed · U2OS · 48 h · 1 → 10 µM. All 1,694 features share one scale. Pick a feature to read its values; the CSV has full precision.

What was tested

Prediction error is mean squared error, averaged within each compound and then across compounds. The 43.0% and 5.5% reductions use all reference compounds (Table 2). The interactive chart shows one archived pemetrexed example.

WHAT IT MEANS FOR YOUR EXPERIMENTS

Plan the next dose with what you have.

If you have measured the lower dose, you already have a starting point for planning the next one. This result shows how accurate the prediction was for 292 compounds in U2OS cells, next to how well a repeat measurement agrees.

Discuss an experiment →

Sources

The figures and tables cited here are in the study archive, with the full comparisons, data and records for reproducing them.

Study data and records ↗Figure 1d; Supplementary Table 22Research code ↗Research code v4.22Chart data list ↓Sources and SHA-256 checksums for every chart downloadChecksum of this list ↓SHA-256